DesignSeries05884.pngFeature control frame

Mode

Tool

Tool set

Modes for L’outil Insertion de symbole

Feature Control Frame

Dims/Notes

Multiple annotation tools share the same position on the tool set in some workspaces. Click and hold the mouse on the visible tool to open the Sous-outils list and select the desired tool.

A feature control frame consists of a geometric characteristic symbol, up to two tolerance areas, and up to three datum reference areas.

Feature_Ctrl.png 

To insert a feature control frame:

Click the tool and mode.

Click to place the object, and click again to set the rotation. The first time you use the tool in a file, a properties dialog box opens. Set the default parameters. The parameters can be edited later from the Object Info palette.

To add a leader and marker, click the Selection tool from the Basic palette and drag the control points on the object. Edit the marker from the Attributes palette (see Marqueurs).

Parameter

Description

Rotation

Specifies the number of degrees to rotate the object (0.00 is horizontal)

Text Style

Select a text style from a library or the current file. To use the style defined for the object’s class, select <Class Text Style>. To format the text using options on the Text menu, select <Un-Styled>. See Utiliser des styles de texte and Mettre en forme du texte.

Geometric Characteristic

Select the geometric characteristic symbol, if any

Dimensions05887.png 

Composite Box

Increases the size of the geometric characteristic box; this is used when placing a second feature control frame

FC_double.png 

Tolerance Area #1/#2

Includes Tolerance Area #1 and/or Tolerance Area #2

Tolerance

Enter the tolerance value

Show Diameter Symbol

Displays a diameter symbol along with the tolerance value

FC_diameter.png 

Material Condition

Choose the material condition, if any

Dimensions05890.png 

Statistical Tolerance

Displays a statistical tolerance symbol

FC_stat.png 

Projected Tolerance Zone

Displays a projected tolerance zone symbol

Zone Height

Enter the maximum projected tolerance zone height when a projected tolerance zone symbol is displayed

Place the PTZ symbol outside the FCF

Places the projected tolerance zone symbol outside and to the bottom of the feature control frame

FC_place_outside.png 

Primary/Secondary/Tertiary Datum Reference

Includes the primary, secondary, and/or tertiary datum reference

Reference

Enter the desired reference letter

Material Condition

Select a material condition, if any

Dimensions05893.png 

Leader Position

Select left or right